Fluoropolymer - PFA (Perfluoro Alkoxy) Compact design occupying 1/2 the space of previous sensors, with a thickness of just 10mm.
Detection method
Infrared Photo-refraction
Output
Transistor NO or NC
NPN (50mA MAX) or PNP (18mA MAX)
Power
12 – 24VDC
Response time
< 1 sec (DI water)
Current Consumption
25mA Max
Indicators
Normal operation – Green LED on, Red LED off
Detection – Red LED on, Green LED off
Operating temperature
- 10 to 60°C
Material of construction
PFA
Cable
shielded 2 conductor, FEP
2 meter length standard
Wiring
+: brown
-: shield or blue
Signal: white or black